ABB conductivity analysers are designed to meet the most exacting requirements of our valued customers. The extensive range covers 2 and 4-wire analysers and single or dual-input devices.
Our hazardous area certifications embrace FM, CSA and CENELEC ATEX intrinsic safety. Instruments are available with HART, Profibus PA or DP, and Fieldbus Foundation communications capabilities.
2-Electrode Contacting Cells - Range 0 to 10,000 µS/cm
High accuracy technique for trace conductivities from ultrapure water to industrial rinse waters. An alternating current is passed between two electrodes in contact with a solution. The transmitter converts the resultant potential difference into conductivity, concentration or specific resistance.
2-Electrode Contacting Cells (United States Pharmacopœia <645>)
Traceable calibration instruments for WFI and PW processes in the Pharmaceutical Industry.
4-Electrode Contacting Cells - Range 0 to 2,000 mS/cm
Auto-compensating technology for high level conductivity and concentration measurements in high-coating processes. Provides an alarm when cleaning is required.
Electrodeless sensors - Range 0 to 2,000 mS/cm
Non-contact technique providing immunity to polarisation, oily fouling and non-conducting coatings until gross fouling occurs. Measurement of the magnitude of induced AC into a closed loop of solution using two embedded toroids.
2-Electrode Contacting Cells - Range 0 to 10,000 µS/cm
 | AX410 | AX411 | AX416 | TB82TE* |
 | | | |  |
| Input 1 | µS/cm | µS/cm | µS/cm |  |
| Input 2 | - | µS/cm | pH |  |
| Application | 4-wire AC & 24V DC | 4-wire AC & 24V DC | 4-wire AC & 24V DC |  |
| Communications | 4 to 20mA, Profibus DP | 4 to 20mA, Profibus DP | 4 to 20mA, Profibus DP |  |
| Mounting | Panel, Wall, Pipe | Panel, Wall, Pipe | Panel, Wall, Pipe |  |
[
 | TB82TE* | TB84TE* |  |  |
 | | |  |  |
| Input | µS/cm | µS/cm |  |  |
| Application | 2-wire 24V DC | 4-wire AC |  |  |
| Communications | 4 to 20mA, HART, FF,
Profibus PA | 4 to 20mA |  |  |
| Mounting | Panel, Wall, Pipe | Panel, Wall, Pipe |  |  |
* Range 0 to 20,000 µS/cm
[
[
[
2-Electrode Contacting Cells - United States Pharmacopœia <645>
 | AX450 | AX455 |  |  |
 | | |  |  |
| Input 1 | µS/cm | µS/cm |  |  |
| Input 2 | - | µS/cm |  |  |
| Application | 4-wire AC | 4-wire AC |  |  |
| Communications | 4 to 20mA, Profibus DP | 4 to 20mA, Profibus DP |  |  |
| Mounting | Panel, Wall, Pipe | Panel, Wall, Pipe |  |  |
[[
[
[
4-Electrode Contacting Cells - Range 0 to 2,000 mS/cm
 | AX430 | AX436 | TB82EC** | TB84EC** |
 | | | | |
| Method | 4-electrode | 4-electrode | 4-electrode | 4-electrode |
| Input 1 | µS/cm | µS/cm | mS/cm | mS/cm |
| Input 2 | - | pH | - | - |
| Application | 4-wire AC | 4-wire AC | 2-wire 24V DC | 4-wire AC |
| Communications | 4 to 20mA, Profibus | 4 to 20mA, Profibus | 4 to 20mA, HART,
FF, Profibus PA | 4 to 20mA |
| Mounting | Panel, Wall, Pipe | Panel, Wall, Pipe | Panel, Wall, Pipe | Panel, Wall, Pipe |
** Range 0 to 400 mS/cm
[[
[
[
Electrodeless sensors - Range 0 to 2,000 mS/cm
 | TB82TC** | TB84TC** |  |  |
 | | |  |  |
| Method | Electrodeless | Electrodeless |  |  |
| Input 1 | mS/cm | mS/cm |  |  |
| Input 2 | - | - |  |  |
| Application | 2-wire 24V DC | 4-wire AC |  |  |
| Communications | 4 to 20mA, HART,
FF. Profibus PA | 4 to 20mA |  |  |
| Mounting | Panel, Wall, Pipe | Panel, Wall, Pipe |  |  |